CS75L series catalog
PRODUCTSPECIAL FEATURESENVIRONMENTALELECTRICAL SPECIFICATIONS
INPUT
- Voltage ......................................... CS75L : AC90V - 132V (note1) CS75 : AC170V - 264V (or DC 240 - 340V)(note1)
- Current ......................................... 1.7A max. (CS75L) / 0.9A Max. (CS75)
- Frequency .................................... 47 - 440Hz max. (50~60Hz typ.)
- Efficiency ..................................... 77 - 86% typ.
- Inrush current (at cold start) ........ 20A max. @ 110VAC. (CS75L) / 40A max. @ 220Vac (CS75)
- Leakage current ........................... 0.5mA max. @ 110VAC (CS75L) / 0.75mA max. @220Vac (CS75)

OUTPUT
- Voltage tolerance ........................ ±10% typ.
- Ripple and noise ......................... ±1% max.
- Line regulation ............................ ±1% max.
- Load regulation ........................... ±1% max.
- Dynamic load regulation ............. ±3% max.
- Temperature drift ........................ ±1% typ.
- Rising time .................................. 100ms max.
- Holding time ................................ 17ms min.

PROTECTION CIRCUIT
- Over current protection ............... Work Over 105% of rating (Recovers Automatically)
- Over voltage protection ............... Work at 115~140% of rating (Latch-up mode)
- Over temperature protection ....... 80°C min.

ELECTRICALLY ISOLATED
- Input - Output .............................. AC 3KV, 1minute, 10mA / DC 500V, 100Mohms min.
- Input - FG .................................... AC 2KV, 1minute, 10mA / DC 500V, 100MOhms min.
- Output - FG ................................. AC 0.5KV, 1minute, 10mA / DC 500V, 70MOhms min.
(NOTE : For cases where conformance to various safety specs (UL, CSA, CE, etc) are required, input voltage and frequency range will be 100-240VAC, 50/60Hz.)
 
DIMENSIONS