FS60 series catalog
PRODUCTSPECIAL FEATURESENVIRONMENTALELECTRICAL SPECIFICATIONS
 
 INPUT
- Voltage ...........................................
AC85~264V (or DC 110~340V)


- Current ........................................... 0.49A max. @ 110VAC / 0.69A max. @ 220VAC
- Frequency ..................................... 47~440Hz max. (50~60Hz typ.)
- Efficiency ....................................... 68~86% typ.
- Inrush current (at cold start) ...... 30A max. @ 110VAC. / 60A max. @ 220VAC
- Leakage current .......................... 0.5mA max. @ 110VAC / 0.75mA max. @220Vac

OUTPUT
- Voltage tolerance .......................... ±2% (single and uncomplementary dual) / ±3% (complementary dual)
- Ripple and noise ........................... ±1% typ.
- Line regulation .............................. ±1% typ.
- Load regulation ............................. ±1% typ. @ Output1 / ±2% typ. @ Output2,3
- Dynamic load regulation .............. ±3% typ. @ Output1
- Temperature drift .......................... ±1% typ.
- Rising time ..................................... 400ms max.
- Holding time .................................. 10ms min.
 
PROTECTION CIRCUIT
- Output short circuit protection ...... Work at over 105% of rating & recovers automatically
- Over temperature protection ........ 140℃ typ.

ELECTRICALLY ISOLATED
- Input - Output ................................ AC 3KV, 1minute, 10mA / DC 500V, 100Mohms min.
- Input - FG ...................................... AC 2KV, 1minute, 10mA / DC 500V, 100MOhms min.
- Output - FG ................................... AC 0.5KV, 1minute, 10mA / DC 500V, 70MOhms min
DIMENSIONS