CD30 series catalog
PRODUCTSPECIAL FEATURESENVIRONMENTALELECTRICAL SPECIFICATIONS
INPUT
- Voltage ........................................... AC90~264V (or DC 110~340V) (note)
- Current ........................................... 0.89A max.
- Frequency ...................................... 47~440Hz max. (50~60Hz typ.)
- Efficiency ........................................ 77% typ.
- Inrush current (at cold start) ....... 30A max. @ 110VAC. / 60A max. @ 220VAC
- Leakage current ...........................  0.5mA max. @ 110VAC / 0.75mA max. @220Vac
 
OUTPUT
- Output Voltage tolerance ............... ±10% typ. @ Output1
- Ripple and noise ............................ ±1% max.
- Line regulation ................................ ±1% max.
- Load regulation ............................... ±1% max. @ Output1? ±2% max. @ Output2
- Dynamic load regulation .................±3% max. @ Output1
- Temperature drift ............................ ±1% typ.
- Rising time ....................................... 100ms max.
- Holding time ..................................... 17ms min.
- Min Load............................................. Output1 Current > Output2 Current (Dual)
 
PROTECTION CIRCUIT
- Over current protection .................... Over 105% of rating (REcovers Automatically)
- Over voltage protection .................... Work at 115~140°C of rating (Latch-up mode)
- Over temperature protection ........... 80°C min.
 
ELECTRICALLY ISOLATED
- Input - Output ................................. AC 3KV, 1minute, 10mA / DC 500V, 100Mohms min.
- Input - FG ........................................ AC 2KV, 1minute, 10mA / DC 500V, 100MOhms min.
- Output - FG ..................................... AC 0.5KV, 1minute, 10mA / DC 500V, 70MOhms min.
 
(NOTE : For cases where conformance to various safety specs (CE, etc) are required, input voltage and frequency range will be 100-240VAC, 50/60Hz.)
 
DIMENSIONS