INPUT
- Voltage .......................................... CS150L - AC90~132V(note1) CS150 - AC170~264V (or DC 240~340V) (note2)
- Current .......................................... 3.3A max. (CS150) / 1.8A Max. (CS150)
- Frequency ..................................... 47~440Hz max. (50~60Hz typ.)
- Efficiency ....................................... 81 - 90% typ.
- Inrush current (at cold start) .......... 20A max. @ 110VAC.(CS150L) / 40A max. @ 220VAC (CS150)
- Leakage current ............................ 0.5mA max. @ 110VAC (CS150L) / 0.75mA max. @220VAC (CS150)
OUTPUT
- Voltage tolerance ......................... ±10% typ.
- Ripple and noise .......................... ±1% max.
- Line regulation ............................. ±1% max.
- Load regulation ............................ ±1% max.
- Dynamic load regulation .............. ±3% max.
- Temperature drift ......................... ±1% typ.
- Rising time .................................. 100ms max.
- Holding time ................................ 17ms min.
PROTECTION CIRCUIT
- Over current protection ............... Work Over 105% of rating (Auto-restart)
- Over voltage protection ............... Work at 115~140% of rating (Latch-up mode)
- Over temperature protection ....... 80°C min.
ELECTRICALLY ISOLATED
- Input - Output .............................. AC 3KV, 1minute, 10mA / DC 500V, 100Mohms min.
- Input - FG .................................... AC 2KV, 1minute, 10mA / DC 500V, 100MOhms min.
- Output - FG ................................. AC 0.5KV, 1minute, 10mA / DC 500V, 70MOhms min.
NOTE 1: For cases where conformance to various safety specs (CE) are required, input voltage and frequency range will be 100-120VAC, 50/60Hz.
NOTE 2: For cases where conformance to various safety specs (CE) are required, input voltage and frequency range will be 200-240VAC, 50/60Hz.